Industrial IoT & Automation Software

We connect the PLCs and machines already on your floor to live dashboards, alerts, and business systems — over Modbus TCP, OPC UA, and MQTT, with any PLC brand and without replacing equipment that works.

Modbus TCPModbus RTUOPC UAMQTTNode.jsPython

Overview

What we do.

Most plants already produce the data they need. It sits in PLC registers and tags, read by one HMI panel next to the machine and nowhere else. Supervisors walk the floor to find out what is running, and production reports are typed up from clipboards at the end of the shift.

We are a software team. Your PLCs, wiring, and panels stay as they are; we read from them over the protocols they already speak — Modbus TCP, OPC UA, or MQTT — collect the data at the edge, and turn it into live dashboards, alarms, reports, and integrations your team actually uses.

Siemens, Allen-Bradley, Schneider, Mitsubishi, Omron, Delta, and others: if the controller exposes Modbus TCP or OPC UA, we connect directly. Older or proprietary protocols go through a gateway or OPC server, so mixed-brand floors end up in one view.

AnyPLC brand on Modbus TCP or OPC UA
LiveModbus TCP & OPC UA demo to walk through
2017Shipping production software since

Capabilities

What you get with us.

01

PLC & machine connectivity

Read registers and tags over Modbus TCP, Modbus RTU (via gateway), and OPC UA — mapped, scaled, and named so the data makes sense.

02

Edge data collection

Edge services that poll devices, buffer through network drops, and forward clean data over MQTT or HTTPS.

03

Live dashboards & HMI

Web-based machine, line, and plant views on any screen — control room, office, or phone.

04

Alarms & notifications

Threshold and state-based alerts by email, SMS, or app, routed to the shift that can act on them.

05

Historian & reports

Time-series storage for trends, downtime, and OEE, with shift and batch reports generated automatically.

06

ERP & MES integration

Production counts, downtime, and quality data pushed into your ERP, MES, or custom systems — no re-typing.

Why Blueshark

Why teams choose us.

  • Software only — your PLCs and panels stay untouched
  • Brand-agnostic: Modbus TCP, OPC UA, and MQTT
  • Read-only by default; any control writes are explicitly approved
  • One team for connectivity, dashboards, mobile, and ERP

How we work

A process built for momentum.

01

Survey

We list your machines, controllers, protocols, and network, and agree which signals matter and who needs to see them.

02

Pilot

One machine or line connected end to end — data collection, a live dashboard, and alerts — so you judge it on your own floor.

03

Roll out

Remaining lines and sites added in sprints, with reports and ERP integration layered on once the data is trusted.

04

Support

Monitoring of the data pipeline, new machines and tags as you add them, and improvements as needs change.

FAQ

Industrial IoT, HMI, and PLC connectivity.

View all FAQs →
Do we need to replace our PLCs or machines?

No. We are a software team and work with the controllers you already have. We read data over the protocols they support — Modbus TCP, OPC UA, or MQTT — and leave your PLC programs, wiring, and panels as they are.

Which PLC brands do you work with?

Any brand that exposes Modbus TCP or OPC UA, including Siemens, Allen-Bradley, Schneider, Mitsubishi, Omron, and Delta. Older or proprietary protocols can be bridged through a gateway or OPC server, so mixed-brand floors still end up in one system.

Modbus TCP or OPC UA — which do we need?

Modbus TCP is simple and supported almost everywhere, but it exposes raw registers that have to be mapped and scaled by hand. OPC UA carries named, typed tags with built-in security, which makes larger systems easier to maintain. Many plants use both; we work with whatever your equipment supports.

Can the system control machines, or only monitor them?

We connect read-only by default. Where you want control actions such as setpoint changes or remote resets, we add them deliberately, behind role-based access, confirmations, and an audit log — and only with your controls engineer’s sign-off.

Does our data stay on-premise?

It can. Data collection, storage, and dashboards can run entirely on a server inside your plant network, in the cloud, or as a hybrid with an edge device forwarding selected data over an encrypted connection. You decide what leaves the site.

Do you do panel wiring, PLC programming, or commissioning?

No — we focus on software: connectivity, data, dashboards, HMI design, and integrations. We work alongside your maintenance team or system integrator for anything inside the panel.

Can we see it working before we commit?

Yes. We have a working demo that reads live data over Modbus TCP and OPC UA and shows it on dashboards with alerts. After the demo, we usually propose a pilot on one machine or line.

Let's Talk

Tell us which machines and PLCs you run and what you want to see. We will show you our Modbus TCP and OPC UA demo and scope a pilot on one line.

Want to see your machine data live?

All services →